What Should Be Done When Bulk Fabric Fails a Pre-Production Lab Test?
- Share
- Issue Time
- Nov 2,2026
Failed bulk fabric should be held pending investigation and approved resolution.
A failed requirement needs a documented hold, investigation, and approved corrective action before material release. Identify whether the cause concerns the substrate, process, or specification, and retest affected properties after changes rather than accepting a replacement solely because its appearance seems similar. Prevent cutting before disposition is agreed.